Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data LossThis on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU750RTXLCD2UN provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP36RT, sold separately).
Pre-Installed LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA Outlets Protect Your Connected Components
Eight 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power. The LCD rotates to accommodate both rack-mount and tower installation.
Automatically Turns Back On After Power Is Restored
Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even after a complete battery discharge.
Product Information |
|
Transource eSKU |
1000337408 |
Manufacturer |
Tripp Lite by Eaton |
Manufacturer Part Number |
SU750RTXLCD2UN |
Manufacturer Website Address |
https://tripplite.eaton.com/ |
Brand Name |
Tripp Lite by Eaton |
Product Line |
SmartOnline |
Product Model |
SU750RTXLCD2UN |
Product Name |
SmartOnline SU750RTXLCD2UN 750VA Rack-mountable UPS |
Product Type |
Double Conversion Online UPS |
Technical Specifications |
|
Technical Information |
Plug/Connector Type |
NEMA 5-15P |
Receptacle Type |
NEMA 5-15R |
Receptacle Detail |
6 x NEMA 5-15R |
Dataline Protection |
RJ-11 |
Dataline Protection |
RJ-45 |
Overload Protection |
Yes |
Transfer Time |
0 ns |
EMI/RFI Noise Filter |
Yes |
Phase |
Single Phase |
Energy Saving |
Green Energy-Saving |
Application/Usage |
Mission Critical Equipment |
Application/Usage |
Data Center |
Application/Usage |
Computer Room |
Application/Usage |
Network Closet |
Application/Usage |
Server |
Power Description |
Load Capacity (VA) |
750 VA |
Load Capacity (Watt) |
675 W |
Input Voltage |
120 V AC |
Output Voltage |
100 V AC |
Output Voltage |
110 V AC |
Output Voltage |
115 V AC |
Output Voltage |
127 V AC |
Input Frequency |
60 Hz |
Output Frequency |
60 Hz |
Waveform Type |
Pure Sine Wave |
Surge Energy Rating |
570 J |
Management |
Network Management |
SNMP/HTTP Remote Monitoring |
Alarm |
UPS StartUp |
Alarm |
Power Failure |
Alarm |
Low Battery |
Alarm |
Overload |
Alarm |
UPS Fault |
Alarm |
Remote Shutdown |
Controls/Indicators |
Status Indicators |
7 Front Panel LEDs Indicator: - AC To DC Conversion
- Battery Mode Operation
- Inverter Mode
- ECO Mode Operation
- Bypass Mode Operation
- AC Output Status
Front Panel LCD Display: - UPS And Site Power Status And Operating Data
- Configuration Of Voltage
- Frequency
- Operating Mode
- Alarm Function And A Variety Of Additional Options
|
Interfaces/Ports |
Serial Port |
Yes |
EPO Port |
Yes |
USB (HID Compliant) Port |
Yes |
Battery Information |
DC System Voltage |
24 V DC |
Backup/Run Time (Full Load) |
4.30 Minute |
Backup/Run Time (Half Load) |
13.90 Minute |
Typical Battery Recharge Time |
3 Hour |
Hot Swappable |
Yes |
Replaceable Battery |
Yes |
Environmental Conditions |
Maximum Operating Temperature |
104°F (40°C) |
Storage Temperature |
5°F (-15°C) - 122°F (50°C) |
Maximum Operating Elevation |
10000 ft |
Sound Emission (A-Weighted) |
45 dB(A) |
Physical Characteristics |
Height |
3.5" |
Width |
17.5" |
Depth |
12.5" |
Rack Height |
2U |
Form Factor |
Rack-mountable |
Weight (Approximate) |
27.60 lb |
Miscellaneous |
Package Contents |
750VA 675W 120V Double-Conversion UPSWEBCARDLXE network management cardUSB cableDB9 cableRack-mounting hardwareTower support standsSafety instructionsQuick start guide |
Country of Origin |
China |
Environmentally Friendly |
Yes |
Environmental Compliance |
Restriction of Hazardous Substances (RoHS) |
Warranty |
Limited Warranty |
2 Year |