Tripp Lite's 120V 15A metered PDU system with Automatic Transfer Switching (ATS) is an 8 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned on at 250 milliscond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 8 NEMA 5-15R outlets, and two 12 ft. 5-15P input power cord. Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual input cabling can be configured for UPS maintenance bypass of standard UPS s
More from the Manufacturer
Product Information |
|
Transource eSKU |
1000179793 |
Manufacturer |
TRIPP LITE |
Manufacturer Part Number |
PDUMH15AT |
Manufacturer Website Address |
https://tripplite.eaton.com/ |
Brand Name |
Tripp Lite by Eaton |
Product Model |
PDUMH15AT |
Product Name |
PDUMH15AT PDU Metered ATS 120V 15A 8 Outlet |
Product Type |
PDU |
Technical Specifications |
|
Technical Information |
Plug/Connector Type |
NEMA 5-15P |
Plug/Connector Detail |
2 x NEMA 5-15P |
Receptacle Type |
NEMA 5-15R |
Receptacle Detail |
8 x NEMA 5-15R |
Power Description |
Input Voltage |
120 V AC |
Output Voltage |
120 V AC |
Power Rating (VA) |
1800 VA |
Management |
Management |
- Optional Automatic Transfer Switch (ATS) function enables for hot-swappable UPS maintenance bypass
- Dual UPS protection or dual AC input redundancy for critical single-corded network hardware
- Slot for optional SNMPWEBCARD accessory to enable remote individual outlet control over IP
|
Physical Characteristics |
Mount Type |
Rack-mountable |
Rack Height |
1U |
Height |
1.8" |
Width |
17.5" |
Depth |
14.5" |
Weight (Approximate) |
11 lb |
Miscellaneous |
Package Contents |
- PDUMH15AT PDU Metered ATS 120V 15A 8 Outlet
- PDU with attached 5-15P input power cord
- Detachable C13 to NEMA 5-15P 12 ft/3.6m power cord for optional secondary input
- User manual with warranty information
|
Country of Origin |
Taiwan |
TAA Compliant |
Yes |
Environmentally Friendly |
Yes |
Warranty |
Limited Warranty |
2 Year |