The CyberPower Smart App Online OL6000RT3UTAA UPS has been manufactured to comply with the Federal Trade Agreement Act (TAA). This network-grade UPS protects mission-critical servers, routers and telecom equipment with true sine wave output and double-conversion topology for seamless power protection. The OL6000RT3UTAA also offers generator compatibility and delivers clean AC power with zero transfer time.
Other features include a flexible rack/tower design for easy installation, extendable LCD control panel, Smart Battery Management, Fast Charge Technology, and energy-saving GreenPower UPS™ ECO Mode. The CyberPower OL6000RT3UTAA UPS is protected by a three-year warranty as well as a $300,000 Connected Equipment Guarantee.
Data Line Protection
Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.
Double-Conversion TopologyProvides consistent, clean, and nearly perfect power, regardless of the condition of incoming power. Systems with this technology operate on isolated DC power 100% of the time and have a zero transfer time because they never need to switch to battery. Double-conversion UPS systems are designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
Sine Wave OutputProvides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.
Extendable LCD PanelDisplays UPS statuses and customizable operating settings from up to 10 ft. away (with optional cable). The extendable LCD control panel can be configured in English, Spanish, or French for ease of use.
Extended Battery Module (EBM)Extends runtime by adding EBMs. This UPS allows for up to ten added modules.
Fast Charge TechnologyAllows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM. Restores a complete charge within 5 hours regardless of the number of EBMs.
Smart Battery Management (SBM)Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
GreenPower UPS™ ECO ModeImproves UPS efficiency up to 96%; saves on electrical and cooling costs.
Hot-Swappable BatteriesEliminate downtime related to UPS power maintenance for continuous power availability.
Critical & Non-Critical LoadsThe UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet. Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.
Emergency Power Off (EPO)Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
Backfeed ProtectionPrevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost. Backfeed protection isolates the UPS and allows service personnel to safely work on the utility power.
Generator CompatibleProvides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
| |
Transource eSKU | 1069955045 |
Manufacturer | CyberPower Systems, Inc |
Manufacturer Part Number | OL6000RT3UTAA |
Manufacturer Website Address | http://www.cyberpowersystems.com |
Brand Name | CyberPower |
Product Line | Smart App Online |
Product Model | OL6000RT3UTAA |
Product Name | OL6000RT3UTAA TAA UPS Systems |
Product Type | Dual Conversion Online UPS |
| |
Technical Information |
AVR | Yes |
Plug/Connector Type | NEMA L6-30P |
Receptacle Type | NEMA L6-20R |
Receptacle Type | NEMA L6-30R |
Receptacle Detail | 2 x NEMA L6-30R |
Receptacle Detail | 2 x NEMA L6-20R |
Transfer Time | 0 ns |
Phase | Single Phase |
Application/Usage | Server |
Application/Usage | Network Equipment |
Application/Usage | VoIP |
Application/Usage | Critical & Non-critical Load |
Application/Usage | Enterprise Installation |
Application/Usage | Mission Critical Equipment |
Power Description |
Load Capacity | 6000 VA/5400 W |
Input Voltage | 230 V AC |
Input Voltage | 120 V AC |
Input Voltage Range | 120 V AC - 139 V AC |
Input Voltage Range | 140 V AC - 159 V AC |
Input Voltage Range | 160 V AC - 179 V AC |
Input Voltage Range | 180 V AC - 280 V AC |
Output Voltage | 200 V AC |
Output Voltage | 208 V AC |
Output Voltage | 220 V AC |
Output Voltage | 230 V AC |
Output Voltage | 240 V AC |
Waveform Type | Sine Wave |
Battery Information |
Battery Chemistry | Lead Acid |
Backup/Run Time (Full Load) | 5 Minute |
Backup/Run Time (Half Load) | 15 Minute |
Typical Battery Recharge Time | 4 Hour |
Hot Swappable | Yes |
Replaceable Battery | Yes |
Physical Characteristics |
Height | 5.3" |
Width | 17" |
Depth | 26" |
Rack Height | 3U |
Form Factor | Rack/Tower |
Weight (Approximate) | 55 lb |
Miscellaneous |
Package Contents | - OL6000RT3UTAA TAA UPS Systems
- Mounting Hardware
|
Energy Star | Yes |
Environmentally Friendly | Yes |
Environmental Certification | RoHS |
Environmental Certification | GreenPower UPS |
TAA Compliant | Yes |
Warranty |
Limited Warranty | 3 Year |