APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Product Information |
|
Transource eSKU |
1000338696 |
Manufacturer |
Schneider Electric SA |
Manufacturer Part Number |
APDU10350ME |
Manufacturer Website Address |
http://www.schneider-electric.com |
Brand Name |
APC by Schneider Electric |
Product Line |
NetShelter |
Product Name |
NetShelter 48-Outlets PDU |
Packaged Quantity |
1 |
Product Type |
PDU |
Technical Specifications |
|
Technical Information |
PDU Type |
Metered |
Phase |
Three Phase |
Plug/Connector Type |
IEC 60309 30A 3P+N+PE |
Receptacle Type |
IEC 60320 C13/C15/C19/C21 |
Receptacle Type |
IEC 60320 C13/C15 |
Receptacle Detail |
24 x IEC 60320 C13/C15/C19/C21 |
Receptacle Detail |
24 x IEC 60320 C13/C15 |
Power Description |
Input Voltage |
415 V |
Input Voltage |
480 V |
Input Voltage Range |
200 V AC - 240 V AC |
Input Voltage Range |
346 V AC - 415 V AC |
Output Voltage |
240 V AC |
Power Rating (VA) |
17.30 kVA |
Power Rating (Watt) |
17.30 kW |
Input Current |
30 A |
Interfaces/Ports |
Network (RJ-45) |
Yes |
Physical Characteristics |
Product Color |
Black |
Mounting Orientation |
Vertical |
Form Factor |
Rack |
Rack Height |
0U |
Cord Length |
5.91 ft |
Height |
70.1" |
Width |
2.2" |
Depth |
3" |
Weight (Approximate) |
18.52 lb |
Environmental Conditions |
Minimum Operating Temperature |
23°F (-5°C) |
Maximum Operating Temperature |
140°F (60°C) |
Minimum Storage Temperature |
-13°F (-25°C) |
Maximum Storage Temperature |
149°F (65°C) |
Miscellaneous |
Country of Origin |
India |
TAA Compliant |
Yes |
Environmentally Friendly |
Yes |
Environmental Compliance |
Restriction of Hazardous Substances (RoHS) |
Warranty |
Limited Warranty |
3 Year |
Additional Warranty Information |
3 years repair or replace |